Sem/edx services in Chelmsford, MA right now

Xrf analysis company in Chelmsford, MA right now? Conclusion: Based on the analytical report, the client was able to demonstrate that the particles were consistent with a common aspirin tablet. When the end customer was approached with this report, they remembered that their spouse had taken an aspirin earlier that morning, and had likely used the bottle of water in question to do so. Based on this, the customer was happy, the manufacturing client was satisfied, and the sample was maintained – undestroyed should someone need to examine the sample again or do any more esoteric testing. For an affordable price, the client was able to get piece of mind, and gather information from a very wide range of testing methods quickly and accurately.

Using light microscopes to examine the optical and structural properties of samples is one of the oldest and most useful analytical techniques. MicroVision Labs has several high magnification microscopes, including a powerful Zeiss Axiotech microscope capable of 1800x optical magnification, with additional digital magnification, allowing for visualization of sub-micron structures. PLM allows for the identification of a wide range of particles through the examination of the internal birefringence, or variation in optical indices, within a sample.

How do I submit a sample or a set of samples? To submit a sample or set of samples, please see the page How to Submit Samples. What if I believe my samples are hazardous? We are not equipped to handle or dispose of every kind of hazardous material. Please call us before sending in any potentially hazardous samples. In cases where we are able to analyze your harzardous samples we may not be able to dispose of them and therefore we will return them to you. See more details on here. We are proud to announce that MicroVision Labs is now accredited to the ISO/IEC 17025:2017 standard. This represents over a year of diligent effort from all of our staff to verify and validate our in house SOP’s and transform our quality management system to one that is compliant to this international standard. This certification requires that accredited labs demonstrate that they are competent and can produce technically valid data and results unlike other certifications such as ISO 9001:2015. This represents an obvious value to our clients.

Dust samples were analyzed using polarized light microscopy (PLM) to provide percentages of the particle types present in the samples. MVL was able to determine that there was significant loading of glass fibers in the dust samples with the likely source being contractor’s work in the attic which involved disturbing the fiberglass insulation. The image on the right shows a few distinct glass fibers with a binder material adhered to them, consistent with fiberglass insulation.

The desired chip packages were sectioned from the larger board, and placed in an epoxy mounting cup. The epoxy was mixed and allowed to harden. The resulting epoxy puck was cross sectioned and polished. The epoxy mounting and cross sectioning process gave precise, perfectly preserved cross sectional surfaces through the desired components and their solder bonds. Explore additional details on https://microvisionlabs.com/.